Description
Professional reverse osmosis unit МО6500 4″ from German ECOSOFT with a production capacity of 250lt/h.
This is the most complete plunge and play unit on the market ideal for brackish water up to 3000 mg/L (TDS)
Unit dimensions:
H×W×D: 1450×540×385mm
Weight: 60kg
Packaging: Wooden box
Dimensions of wooden box: H×W×D: 1547×604×449mm
Package weight: 90kg
Standard equipment
- Pump: Grundfos® CM 1-10 multistage pump
- Membrane vessel: 300 psi membrane vessel
- Membrane: Ecosoft ELP-4040 membrane (salt rejection 99.0 % @ 2000mg/L NaCl)
- Prefilter: BB10 sediment prefilter
- Controller: Electrical panel with Ecosoft controller OC5000
- Solenoid valves: Danfoss solenoid valves
- Regulator Recirculation Flowmete
- rRegulating Wastewater Flowmeter
- Produced water flowmeter
- Inlet water pressure gauge
- Waste water pressure gauge
- Wiring: Pre-wired
- Piping: Piped
- Frame: Metal
- Packaging: Wooden box
Optional Equipment
- Dosing anti-scald pump
- Water mixing system (TDS Adjustment) from 30 to 240 litres/hour
- Membrane rinsing system with osmotic water
- Filmtec™ ХLE-4040 membrane for low conductivity waters (salt rejection 99.0 % @ 500mg/L NaCl)
- Filmtec™ LCLE-4040 membrane for medium conductivity waters (salt rejection 99.2 % @ 200mg/L NaCl)
Connections
- Influent water — ½”
- Produced Water (permeate water) — ½”
- Waste Water (concentrate water) — ½”
- Antiscalant dosing port – ½″
- Membrane rinsing with osmotic water – ½″ (optional accessory – kit)
- Raw water mixing with osmotic – 3/8″ QC tubing (optional accessory – kit)
Specifications
- Produced water* — 250 L/h
- Daily Production* — 6500 Lt
- Recovery rate** — 75%
- Maximum TDS — 3000 mg/L
- Inlet water supply – (320 to 400 L/h in normal mode and 1500 to 2000 L/h in membrane flushing mode)
- Operating pressure — 8…12 barMaximum
- Pump Pressure — 14 bar
- Electrical supply — 230 V, 50 Hz (1 ph)
- Pump Power — 0.7 kW
- Solids prefilter — 5 µm
* Depends on the quality and temperature of the incoming water
** For low hardness water
Basic Inlet Water Conditions
- Influent water temperature — +5…+40 °С
- Residual chlorine, max — 0.1 mg/L
- Hardness — up to 3 meq/L (150 mg/L CaCO₃)
- Iron — up to 0.1 mg/L
- Manganese — up to 0.05 mg/L
- Silicate — up to 20 mg/L
- Chemical oxygen demand, max — 4.0 mg О₂/L
- Hydrogen sulphide – none
If the water exceeds the specified limits, we should install pre-filtration stations before the unit.It is good to have a specialized water analysis done before purchasing a unit.
Ecosoft OC5000 controller
Ecosoft’s OC5000 ECU is designed to work automatically or manually and can control the following:
- Automatic start with low pressure switch (Low Pressure switch)
- Automatic shutdown with High Pressure switch
- Pump protection in case of lack of water with dry-running sensors
- Automatic shutdown with external float switch
- Membrane flushing (Auto hydraulic flushing)
- Produced water quality and temperature sensor (electrical conductivity and temperature)
Reviews